Applications

  • Noise at work
  • Environmental noise
  • Prescription of hearing protection
  • Product noise testing
  • Reverberation measurement
  • Speech intelligibility
  • General purpose sound level meter

Features

text
  • Single measurement range.
  • Extremely simple operation.
  • Parallel LAeq and LCpeak.
  • Real time 1/1 octave and 1/3 octave
  • Reverberation time calculation
  • Statistical analysis
  • Level versus time
  • Speech Transmission Index (STIPA) calculation
  • USB interface
  • Large back-lit display

Standards

text
  • IEC 61260-1, IEC 61260-2, IEC 61260-3, IEC 61672-1
  • ANSI S1.4, ANSI S1.11, ANSI S1.43
  • DIN 45657, TA-Lärm
  • NS 4814, NS 4815, NS 8172

Options

text

The Nor131 and Nor132 sound level meters may be extended with a selection of optional features that may be ordered and installed at any time.

Option packages*:

Nor131/RA options package including option 1,5,6.
Nor131/ENV options package including option 1,2,3,4,7.
Nor131/ALL options package including option 1,2,3,4,5,6,7.

Nor132/RA options package including option 1,5,6.
Nor132/ENV  options package including option 1,2,3,4,7.
Nor132/ALL options package including option 1,2,3,4,5,6,7.

*Instrument must be purchased separately.

Option 1 : Frequency analysis - 1/1 octave filters

text

The Nor130 series of SLM’s may be extended with digital real-time 1/1-octave filters. This feature is available through the installation of option 1, and covers 12 frequency bands in the range from 8Hz to 16kHz.

Within each band, the instrument will measure the SPL, Leq, LMax, LMin and LE functions. Additionally, if the Option 2 Statistical analysis is installed, 8 different LN-percentiles are calculated within each 1/1-octave band.

  • A-preweighting feature available on display results.
  • All filters fulfill the IEC 61260 class 1 digital IIR base 10 requirements.
  • 120 dB “one-range” even in the filter bands.
  • Results are displayed both graphically and numerically.
Nor131 and Nor132 Option 1 -The 1/1-octave spectrum may be viewed with a A-preweighting feature

Nor131 and Nor132 Option 1 -The 1/1-octave spectrum may be viewed with a A-preweighting feature

Nor131 and Nor132 Option 1 – The 1/1-octave table is scrolled up and down for all measured functions

Nor131 and Nor132 Option 1 – The 1/1-octave table is scrolled up and down for all measured functions

Nor131 and Nor132 Option 1 – Frequency analysis 1/1 octave filters

Nor131 and Nor132 Option 1 – Frequency analysis 1/1 octave filters

Option 2: Statistical Analysis

text
  • Calculate 7 fixed LN values (L1%, L5%, L10%, L50%, L90%, L95% and L99%).
    Parallel calculation of 1 editable LN value selectable within the range 0.1 – 99.9 %.
  • Statistical calculations based on 0.2 dB class widths covering the entire 130 dB range.
  • Parallel statistical calculation on both A- and C-/Z-weighted networks.
  • If real-time filters are installed (option 1 or 3), statistical calculations are available for the individual filter bands as well.

Option 4 adds statistical distribution to the Nor31/Nor132 functionality. There are eight percentiles shown, out of which one is user selectable. The class width is 0.2 dB over the entire 130 dB range.

The statistical distribution calculations employs the F time constant and applies to the spectral weighting networks (A and C or Z) as well as all the individual 1/1 and 1/3-octave filter bands (if applicable). The back-erase feature, which deletes up to the ten most recent seconds of acquired global data prior to a pause upon resuming, updates the statistics buffers as well to maintain consistency.

Nor131 and Nor132 Option 2 – The LN percentage table contains 7 fixed and one user-defined percentile

Nor131 and Nor132 Option 2 – The LN percentage table contains 7 fixed and one user-defined percentile

Option 3 : Level vs Time

text
  • Simultaneous measurement of Global results and Profile results based on a level versus time values at preset intervals
  • Selection of preset intervals within the 1 second to 199 hours interval range
  • Automatic level versus time storage of LAeq, LAmax and LCpeak (or LZpeak)
  • Level versus time measurement continues during a paused Global measurement
  • Markers identify any pause, stop or continue of the measurement
  • To view or report the result simply transer the measurement result to PC using NorXfer and NorReview. Measurement results may also be automatically converted to Excel using NorXfer

Option 4: 1/3-octave real-time filters

text

The Nor130 series of SLMs may be extended with digital real-time 1/3-octave filters. This feature is available through the installation of option 4.

Within each band, the instrument will measure the SPL, Leq, LMax, LMin and LE functions. Additionally, if the Option 2 Statistical analysis is installed, 8 different LN-percentiles are calculated within each 1/3-octave band.

  • Parallel 1/3-octave real-time filters covering the 6.3 – 20000 Hz frequency range.
  • All filters fulfill the IEC 61260 class 1 digital IIR base 10 requirements.
  • A-preweighting feature available on display results.
  • 120 dB “one-range” even in the filter bands.
  • Results are displayed both graphically and numerically.
Nor131 and Nor132 Option 4 – 1/3-octave spectrum

Nor131 and Nor132 Option 4 – 1/3-octave spectrum

Nor131 and Nor132 Option 4 – A-weighed spectrum

Nor131 and Nor132 Option 4 – A-weighed spectrum

Option 5: Reverberation time measurement mode

text

Reverberation time measurement mode is now available on the sound level meter Nor131 and Nor132.

  • Reverberation time based on impulse excitation
  • Calculates both T20 and T30
  • Covers the 63 – 8000 Hz frequency bands for the 1/1-octave filters
  • Covers the 50 – 10000 Hz frequency bands for the 1/3-octave filter

Option 5 requires that option 1 is installed!

Nor131 and Nor132 Option5 – Reverberation time measurement mode

Nor131 and Nor132 Option5 – Reverberation time measurement mode

Option 6: STIPA (Speech Transmission Index) measurement mode

text
  • Calculates the STIPA speech transmission index
  • Fulfils the requirements of the latest IEC 60268-16 ed. 5 Standard for STIPA
  • Includes signal (.vaw) for use through separate public address
  • Loudspeaker system or portable CD-player can be used for playback of signal
  • Background noise correction

It is now possible to use the Nor131 and Nor132 meters for analysing the Speech Transmission quality in public areas using the STIPA method. The method can be used to compare the speech transmission quality at various positions and under various conditions within the same listening space. The calculation follows the latest revision of the standard..

A measurement in one listening position takes about 13 sec. Unlike many other STIPA measurement systems, the implementation with the Nor131/132 can also correct the results for the background noise. In addition all calculated indexes are displayed, not only the single STIPA value. This feature is valuable for engineers optimizing the room acoustics in public spaces or other areas where the speech quality is important.

Option 6 requires that option 1 is installed!

Nor131 and Nor132 Option 6 – STIPA (Speech Transmission Index) measurement mode

Nor131 and Nor132 Option 6 – STIPA (Speech Transmission Index) measurement mode

Options 7: Parallel F, S, I

text

Measures all 3 time constants simultaneously.

Specifications

text

The Nor130 series of SLM fulfil the following Sound Level Meter and 1/1&1/3 octave filter standards: IEC 61260-1, IEC 61260-2, IEC 61260-3, IEC 61672-1, ANSI S1.4, ANSI S1.11, ANSI S1.43, DIN 45657. The Nor131 instrument meets the Class1 requirements while the Nor132 instrument the Class 2 requirements.

English, French and German language support.

Measured Parameters

Simultaneous measurement of SPL, Leq, LMax, LMin, LE and LPeak (plus the Tmax5 for Germany only).
Time weighting functions: Fast, Slow and Impulse.

Spectral weighting functions: Simultaneously measurement of A and C or Z-weighting. Additionally the 1/1 octave real time filters covering all bands from 8 Hz to 16K Hz (option 1) or 1/3-octave covering all bands from 6,3Hz to 20kHz (option 4).

Statistical calculations: 7 fixed percentiles L1%, L5%, L10%, L50%, L90%, L95%, and L99% plus one user defined value (f.ex. L0.1%). The statistical calculation is performed in real time within each frequency band if the filter option 1 is installed.

Measurement range

One range covering 120dB without any range adjustments.
Self noise measured with microphone: 17dBA (25dBA for Nor132)
Maximum RMS level: 137dBA
Maximum Peak level: 140dB PeakC
Levels up to 174dB can be measured by use of a suitable 1/4” microphone.

Battery / power consumption

Battery: 4 cells, IEC LR6, AA-sized, Alkaline batteries are recommended (e.g. Duracell Ultra M3). AA-sized NiCd or NiMH rechargeable batteries may be used, but must be charged outside the instrument. Battery voltage and time on battery since last change of bat-teries are indicated.
Typical battery life time (Duracell Ultra M3): 8 – 12 hours.

External dc: 11 – 16 volt. Power consumption approximately 1.2 watt dependent on selected modes of operation. External DC source should have source-impedance less than 1 ohm and be able to supply at least 300 mA. The mains adaptor Nor340 is recommended for use with the instrument.

If the external supply falls below 9 V, the instrument will use the internal batteries if available. If the instrument has switched off due to loss of power or insufficient supply voltage, the instrument will automatically switch on after reapplying the external DC supply.

Display

The display is a monochrome, trans-reflective LCD graphical display with 160×240 pixels (W×H) with automatic temperature compensation for contrast and viewing angle. Pressing the light key illuminates the display. The light switches off automatically 2 minutes after the last operation of any key.
The bar graph display covers 80 dB, which may be scrolled in 10 dB steps to cover the total range.

Data storage / Data transfer

Measured data is stored in the internal memory of the sound level meter. The memory is of the “flash” type retaining the information without battery supply. Approximately 5 Mbyte is available for the data storage. This corresponds 10 000 measurements for sound level meters without octave analysis and up to 2 500 for sound level meters with octave analysis.

Data transfer via USB 2.0 interface.

Analogue input

Input connector: TNC connector for Norsonic microphone systems.
Preamplifier: Nor1207 IEPE.
Polarisation voltage: 0 V (pre-polarized)
Supply current: 3mA
Supply voltage: 24V
Input impedance: > 100 kohm, <650 pF
Measurement range: 0.3 mV to 7 V (RMS) in one range corresponding to –10 dB to 137 dB with a microphone sensitivity of 50 mV/Pa. The maximum peak value ±10 V corresponds to 140 dB.
Microphone: Nor1228

Analogue outputs

The analogue output is a reproduction of the digitized input signal from the microphone (or input connector) obtained by a digital to analogue converter.
Output voltage: Full scale on the display corresponds to 100 mV.
Output impedance: The loading impedance shall be 16 ohm or greater. The output is short-circuit proof to GND.
Gain accuracy at 1 kHz: ±0.2 dB.
Frequency response re. 1 kHz: ±0.5 dB for 20 Hz < f < 16 kHz.

Environmental conditions

Reference conditions: The reference conditions for the instrument are as specified by IEC 61672-1 .
Temperature: 23°C
Humidity: 50% RH
Atmospheric pressure: 101.325 kPa

Environmental conditions for operation

Temperature: –10°C to +50°C
Humidity: 5% to 90% RH, dewpoint less than 40°C Atmospheric pressure: 85 kPa to 108 kPa

Environmental conditions for storage

Temperature: –30°C to +60°C
Humidity: 5% to 90% RH, dewpoint less than 40°C Atmospheric pressure: 50 kPa to 108 kPa

Dimensions

Depth: 29 mm
Width: 74 mm
Length, excl. microphone/preamplifier: 215 mm,
Length, incl. microphone/preamplifier: 305 mm
Weight incl. batteries: 380 g

Accessories

text

Sound level meters

Nor340A Mains adaptor

Sound level meters

Nor1335A Softbag

Sound level meters

Nor1434 Windscreen, 90mm

Sound level meters

Nor1451 Windscreen, 60mm

Sound level meters

Nor1261 Tripod adaptor

Downloads

text
Brochurer

Product range catalogue

  • Product range catalogue -

    Norsonic_productrange_catalogue_web.pdf (9762.29KB)
    Released
Software

USB drivers

  • USB driver -

    CDM-v2.12.28-Norsonic.zip (2245.19KB)
    Released
Software

NorXfer

  • NorXfer Nor1020 - 6.2.1

    NorXfer-6.2.1.zip (0.03GB)
    Released 04/03/2024
Software

Nor1026 NorReview

  • NorReview Nor1026 - 5.2.38

    NorReview5.2.38.zip (0.07GB)
    Released 08/03/2019
  • NorReview - 6.3.49

    NorReview-6.3.49.zip (0.1GB)
    Released 22/12/2022
  • NorReview - 6.4.36

    NorReview-6.4.36.zip (0.07GB)
    Released 17/04/2024
Software

NorVirtual

  • NorVirtual - 5.0.240212

    NorVirtual-5.0.240212.zip (0.03GB)
    Released 26/02/2024
Instrument software

Instrument software Nor131/Nor132 and Nor139

  • Nor13x - 3.0.1866

    13xv3_0_1866Released.zip (979.94KB)
    Released 27/08/2020
  • Nor13x - 4.0.1550

    13xv4_0_1550Released.zip (1043.94KB)
    Released 14/03/2024
  • NorUpdate - 1.6.01

    NorUpdate-1.6.01.zip (5206.97KB)
    Released

    Follow these steps when upgrading the firmware: 

    • Download the latest version of NorUpdate. This program must be installed on the PC from where you connect the instrument that shall be upgraded
    • Download and store the instrument firmware update pack. You may save it on any directory on your PC.
    • Unzip the instrument firmaware. You may be promted for a password. Contact Norsonic or your local dealer.
    • Start NorUpdate. Make sure that the path to files are set correctly. This is found in the “File menu”
    • Follow the instructions given in the NorUpdate sofware.

    Please note! Instruments sold in France, Austria, Germany, Spain and Switzerland is subjected to use pattern evaluated software only. Users in these countries are requested to contact their local Norsonic representative to get the current type approved version.

    Achtung! In Deutschland, Österreich, Spanien und der Schweiz unterliegen Schallmessgeräte einer Bauartzulassung / Baumusterprüfung. Die Firmware des Messgerätes ist Bestandteil dieser Bauartzulassung. Führen Sie daher bitte selber kein Firmware-Update durch, sondern wenden sich bei Interesse / Fragen an Ihren lokalen Norsonic-Vertreter!

    Attention ! Les instruments vendus en France, Suisse, Allemagne, Autriche et Espagne doivent être configurés exclusivement avec le logiciel homologué. Dans ces pays, les utilisateurs sont priés de contacter leur représentant local Norsonic pour obtenir la version actuelle approuvée.

    Por favor, tenga en cuenta que los instrumentos vendidos en España, Austria, Alemania y Suiza deben usarse exclusivamente con el software evaluado en el examen de modelo. Se sugiere a los usuarios de estos países que contacten con los distribuidores locales para obtener la versión aprobada en la actualidad.

Software

STIPA IEC 60268-16 ed. 5

  • STIPA - IEC 60268-16 ed. 5 standard -

    (0KB)
    Released

    EC 60268-16 (Ed.5.0 2020): Sound system equipment – Part 16: Objective rating of speech intelligibility by speech transmission index.
    The CIS-value is calculated from the STI-value as specified in: IEC 60849 (Ed. 2.0 1998-02) Sound systems for emergency purposes. (Withdrawn 2008).
    The instrument measures STIPA as specified in Annex B of IEC286-16 by the direct method.

Software

STIPA v4

  • STIPA v4 -

    (0KB)
    Released

    IEC 60268-16 (Ed.4.0 2011-06): Sound system equip-ment – Part 16: Objective rating of speech intelligibility by speech transmission index.
    The CIS-value is calculated from the STI-value as specified in:
    IEC 60849 (Ed. 2.0 1998-02) Sound systems for emer-gency purposes.

Type approvals

Type approvals Nor131 and Nor132

  • Type approval PTB - Germany -

    PTB_131.pdf (741.03KB)
    Released
  • Type approval BEV - Austria -

    Nor132-Type-approval-BEV.pdf (94.26KB)
    Released
  • Type approval - Serbia -

    Nor131_Serbia.pdf (380.99KB)
    Released
  • Type approval METAS – Switzerland -

    METAS_Zulassungszertifikat-CH-A3-18085-00_Nor131_August-2018.pdf (1623.51KB)
    Released
  • Type approval CMI - Czech Republic -

    Nor131-Type-approval-Czech.pdf (195.99KB)
    Released
Certificates

Certificates Nor131 and Nor132

  • Declaration of Conformity -

    DOC_Nor131-Nor132-sound-level-meter.pdf (37.5KB)
    Released

Support